Specifications Double chamber incinerator
Primary combustion
Diesel/LPG/LNG burning primary combustion chamber/primary combustion zone 
Secondary combustion
Residence time in the secondary chamber not less than 2 seconds
Both primary and the secondary temperatures maintained until all the waste has been completely combusted
Chimney

Chimney with a minimum height of 4 meters above ground level 
Minimum exit velocity of the emissions not less than 10 metres/second
Temperature Warnings 
Audible and/or visible alarm to warn the operator when the secondary temperature drops to below the required temperature
General
Control box that can be detached and mounted on separate stand at least 1.5 meters from incinerator at approximately 1.6 meter height